High performance aluminum windows and doors

  • Bulletproof FB3(Br3)
    1. Bulletproof Glass System: Bullet Resistance Performance   Standards TR1 TR2 TR3 notes Corresponding Burglarproof resistance performance RC3 RC4 RC6   According to different requirements, clients can customize your TR systems with different bullet resistance performance. European Standards EN1522 Windows, doors, shutters and blinds—Bullet resistance—Requirements and classification  B1 B2-4 B5-7       American Standard   Systems   Rating   Ammunition   Grain   (g)   Minimum velocity fps         (m/s)   Number of shots               UL752 Standard for safety Bullet-Resisting Equipment             All TR systems can be customized with bullet resistance performance from one kind of the ratings based on your requirements.   Level 1   9 mm full metal copper jacket with lead core   124   8.0   1,175       358   3   Level 2   .357 Magnum jacketed lead soft point   158   10.2   1,250       381   3   Level 3   .44 Magnum lead semi-wadcutter gas checked   240   15.6   1,350       411   3   Level 4   .30 caliber rifle lead core soft point   180   11.7   2,540      774   1   Level 5   7.62 mm Rifle lead core full metal copper jacket military ball   150   9.7   2,750      838   1   Level 6   9 mm full metal copper jacket with lead core   124   8.0   1,400       427   5   Level 7   5.56 mm Rifle full metal copper jacket with lead core   55   3.56   3,080       939   5   Level 8   7.62 mm Rifle lead core full metal copper jacket, military ball   150   9.7   2,750       838   5   Note — Maximum velocity is 110 percent of the minimum velocity.     2. More Performances: Building physics Besides KFORTS high security performance, TR system complies with all requirements in building physics up to highest level. It features a slim frame, a concealed sash design, and a wide visible area. Resistance against wind load Water tightness Air permeability Technical parameters: ≥ 16kpa/m ³ (1800 * 1500), Technical parameters: ≥ 700 (PA), Technical parameters:The unit seam length index value is ≤ 0.5m ³ (m · h),The unit area index value is ≤ 1.4 square meters (m · h),Level: 8 (max). Air permeability Sound Insulation Standard: EN673 Standard: GB/T 8485-2008, Technical parameters: 1.87-2.15 W/(㎡· k) Door: 2.158 W/(㎡· k) Window: 1.875 W/(㎡· k) Curtain Wall: 1.873 W/(㎡· k) Technical parameters: ≥ 45 (dB (A)),           3. Design and Sections TR Security Glass Window System  Design examples Single leaf:  Minimum Size: Width = 500mm, Height = 750mm Maximum Size: Width = 800mm, Height = 1800mm Fixed panel:  Minimum Size: Width = 400mm, Height = 400mm Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.      TR Security Glass Window System   Section Examples       Types   Thickness of bullet proof steel plate/mm   Thickness of Glass/mm   EN1627-EN1630 Forced entry resistance   EN1063 Bullet resistance   UL752 Bullet resistance TRW-1  2.5-15 47.5-70 RC3      B1-B7      Level 1-8   TRW-2 RC4 TRW-3 RC6     TR Security Glass Swing Door and Curtain Wall System  Design examples   Single leaf:  Minimum Size: Width = 600mm, Height = 1500mm Maximum Size: Width = 1000mm, Height = 2500mm Fixed panel:  Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.   TR Security Glass Swing Door and Curtain Wall System  Section examples       Types   Thickness of bullet proof steel plate/mm   Thickness of Glass/mm   EN1627-EN1630 Forced entry resistance   EN1063 Bullet resistance   UL752 Bullet resistance TRD-1  2.5-15 47.5-70 RC3      B1-B7      Level 1-8   TRD-2 RC4 TRD-3 RC6     TR Security Glass Sliding Door System Design examples
  • BulletproofFB4(Br4)
    1. Bulletproof Glass System: Bullet Resistance Performance   Standards TR1 TR2 TR3 notes Corresponding Burglarproof resistance performance RC3 RC4 RC6   According to different requirements, clients can customize your TR systems with different bullet resistance performance. European Standards EN1522 Windows, doors, shutters and blinds—Bullet resistance—Requirements and classification  B1 B2-4 B5-7       American Standard   Systems   Rating   Ammunition   Grain   (g)   Minimum velocity fps         (m/s)   Number of shots               UL752 Standard for safety Bullet-Resisting Equipment             All TR systems can be customized with bullet resistance performance from one kind of the ratings based on your requirements.   Level 1   9 mm full metal copper jacket with lead core   124   8.0   1,175       358   3   Level 2   .357 Magnum jacketed lead soft point   158   10.2   1,250       381   3   Level 3   .44 Magnum lead semi-wadcutter gas checked   240   15.6   1,350       411   3   Level 4   .30 caliber rifle lead core soft point   180   11.7   2,540      774   1   Level 5   7.62 mm Rifle lead core full metal copper jacket military ball   150   9.7   2,750      838   1   Level 6   9 mm full metal copper jacket with lead core   124   8.0   1,400       427   5   Level 7   5.56 mm Rifle full metal copper jacket with lead core   55   3.56   3,080       939   5   Level 8   7.62 mm Rifle lead core full metal copper jacket, military ball   150   9.7   2,750       838   5   Note — Maximum velocity is 110 percent of the minimum velocity.     2. More Performances: Building physics Besides KFORTS high security performance, TR system complies with all requirements in building physics up to highest level. It features a slim frame, a concealed sash design, and a wide visible area. Resistance against wind load Water tightness Air permeability Technical parameters: ≥ 16kpa/m ³ (1800 * 1500), Technical parameters: ≥ 700 (PA), Technical parameters:The unit seam length index value is ≤ 0.5m ³ (m · h),The unit area index value is ≤ 1.4 square meters (m · h),Level: 8 (max). Air permeability Sound Insulation Standard: EN673 Standard: GB/T 8485-2008, Technical parameters: 1.87-2.15 W/(㎡· k) Door: 2.158 W/(㎡· k) Window: 1.875 W/(㎡· k) Curtain Wall: 1.873 W/(㎡· k) Technical parameters: ≥ 45 (dB (A)),           3. Design and Sections TR Security Glass Window System  Design examples Single leaf:  Minimum Size: Width = 500mm, Height = 750mm Maximum Size: Width = 800mm, Height = 1800mm Fixed panel:  Minimum Size: Width = 400mm, Height = 400mm Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.      TR Security Glass Window System   Section Examples       Types   Thickness of bullet proof steel plate/mm   Thickness of Glass/mm   EN1627-EN1630 Forced entry resistance   EN1063 Bullet resistance   UL752 Bullet resistance TRW-1  2.5-15 47.5-70 RC3      B1-B7      Level 1-8   TRW-2 RC4 TRW-3 RC6     TR Security Glass Swing Door and Curtain Wall System  Design examples   Single leaf:  Minimum Size: Width = 600mm, Height = 1500mm Maximum Size: Width = 1000mm, Height = 2500mm Fixed panel:  Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.   TR Security Glass Swing Door and Curtain Wall System  Section examples       Types   Thickness of bullet proof steel plate/mm   Thickness of Glass/mm   EN1627-EN1630 Forced entry resistance   EN1063 Bullet resistance   UL752 Bullet resistance TRD-1  2.5-15 47.5-70 RC3      B1-B7      Level 1-8   TRD-2 RC4 TRD-3 RC6     TR Security Glass Sliding Door System Design examples
  • Bulletproof FB5(Br5)
    1. Bulletproof Glass System: Bullet Resistance Performance   Standards TR1 TR2 TR3 notes Corresponding Burglarproof resistance performance RC3 RC4 RC6   According to different requirements, clients can customize your TR systems with different bullet resistance performance. European Standards EN1522 Windows, doors, shutters and blinds—Bullet resistance—Requirements and classification  B1 B2-4 B5-7       American Standard   Systems   Rating   Ammunition   Grain   (g)   Minimum velocity fps         (m/s)   Number of shots               UL752 Standard for safety Bullet-Resisting Equipment             All TR systems can be customized with bullet resistance performance from one kind of the ratings based on your requirements.   Level 1   9 mm full metal copper jacket with lead core   124   8.0   1,175       358   3   Level 2   .357 Magnum jacketed lead soft point   158   10.2   1,250       381   3   Level 3   .44 Magnum lead semi-wadcutter gas checked   240   15.6   1,350       411   3   Level 4   .30 caliber rifle lead core soft point   180   11.7   2,540      774   1   Level 5   7.62 mm Rifle lead core full metal copper jacket military ball   150   9.7   2,750      838   1   Level 6   9 mm full metal copper jacket with lead core   124   8.0   1,400       427   5   Level 7   5.56 mm Rifle full metal copper jacket with lead core   55   3.56   3,080       939   5   Level 8   7.62 mm Rifle lead core full metal copper jacket, military ball   150   9.7   2,750       838   5   Note — Maximum velocity is 110 percent of the minimum velocity.     2. More Performances: Building physics Besides KFORTS high security performance, TR system complies with all requirements in building physics up to highest level. It features a slim frame, a concealed sash design, and a wide visible area. Resistance against wind load Water tightness Air permeability Technical parameters: ≥ 16kpa/m ³ (1800 * 1500), Technical parameters: ≥ 700 (PA), Technical parameters:The unit seam length index value is ≤ 0.5m ³ (m · h),The unit area index value is ≤ 1.4 square meters (m · h),Level: 8 (max). Air permeability Sound Insulation Standard: EN673 Standard: GB/T 8485-2008, Technical parameters: 1.87-2.15 W/(㎡· k) Door: 2.158 W/(㎡· k) Window: 1.875 W/(㎡· k) Curtain Wall: 1.873 W/(㎡· k) Technical parameters: ≥ 45 (dB (A)),           3. Design and Sections TR Security Glass Window System  Design examples Single leaf:  Minimum Size: Width = 500mm, Height = 750mm Maximum Size: Width = 800mm, Height = 1800mm Fixed panel:  Minimum Size: Width = 400mm, Height = 400mm Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.      TR Security Glass Window System   Section Examples       Types   Thickness of bullet proof steel plate/mm   Thickness of Glass/mm   EN1627-EN1630 Forced entry resistance   EN1063 Bullet resistance   UL752 Bullet resistance TRW-1  2.5-15 47.5-70 RC3      B1-B7      Level 1-8   TRW-2 RC4 TRW-3 RC6     TR Security Glass Swing Door and Curtain Wall System  Design examples   Single leaf:  Minimum Size: Width = 600mm, Height = 1500mm Maximum Size: Width = 1000mm, Height = 2500mm Fixed panel:  Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.   TR Security Glass Swing Door and Curtain Wall System  Section examples       Types   Thickness of bullet proof steel plate/mm   Thickness of Glass/mm   EN1627-EN1630 Forced entry resistance   EN1063 Bullet resistance   UL752 Bullet resistance TRD-1  2.5-15 47.5-70 RC3      B1-B7      Level 1-8   TRD-2 RC4 TRD-3 RC6     TR Security Glass Sliding Door System Design examples
  • Bulletproof FB6(Br6)
    1. Bulletproof Glass System: Bullet Resistance Performance   Standards TR1 TR2 TR3 notes Corresponding Burglarproof resistance performance RC3 RC4 RC6   According to different requirements, clients can customize your TR systems with different bullet resistance performance. European Standards EN1522 Windows, doors, shutters and blinds—Bullet resistance—Requirements and classification  B1 B2-4 B5-7       American Standard   Systems   Rating   Ammunition   Grain   (g)   Minimum velocity fps         (m/s)   Number of shots               UL752 Standard for safety Bullet-Resisting Equipment             All TR systems can be customized with bullet resistance performance from one kind of the ratings based on your requirements.   Level 1   9 mm full metal copper jacket with lead core   124   8.0   1,175       358   3   Level 2   .357 Magnum jacketed lead soft point   158   10.2   1,250       381   3   Level 3   .44 Magnum lead semi-wadcutter gas checked   240   15.6   1,350       411   3   Level 4   .30 caliber rifle lead core soft point   180   11.7   2,540      774   1   Level 5   7.62 mm Rifle lead core full metal copper jacket military ball   150   9.7   2,750      838   1   Level 6   9 mm full metal copper jacket with lead core   124   8.0   1,400       427   5   Level 7   5.56 mm Rifle full metal copper jacket with lead core   55   3.56   3,080       939   5   Level 8   7.62 mm Rifle lead core full metal copper jacket, military ball   150   9.7   2,750       838   5   Note — Maximum velocity is 110 percent of the minimum velocity.     2. More Performances: Building physics Besides KFORTS high security performance, TR system complies with all requirements in building physics up to highest level. It features a slim frame, a concealed sash design, and a wide visible area. Resistance against wind load Water tightness Air permeability Technical parameters: ≥ 16kpa/m ³ (1800 * 1500), Technical parameters: ≥ 700 (PA), Technical parameters:The unit seam length index value is ≤ 0.5m ³ (m · h),The unit area index value is ≤ 1.4 square meters (m · h),Level: 8 (max). Air permeability Sound Insulation Standard: EN673 Standard: GB/T 8485-2008, Technical parameters: 1.87-2.15 W/(㎡· k) Door: 2.158 W/(㎡· k) Window: 1.875 W/(㎡· k) Curtain Wall: 1.873 W/(㎡· k) Technical parameters: ≥ 45 (dB (A)),           3. Design and Sections TR Security Glass Window System  Design examples Single leaf:  Minimum Size: Width = 500mm, Height = 750mm Maximum Size: Width = 800mm, Height = 1800mm Fixed panel:  Minimum Size: Width = 400mm, Height = 400mm Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.      TR Security Glass Window System   Section Examples       Types   Thickness of bullet proof steel plate/mm   Thickness of Glass/mm   EN1627-EN1630 Forced entry resistance   EN1063 Bullet resistance   UL752 Bullet resistance TRW-1  2.5-15 47.5-70 RC3      B1-B7      Level 1-8   TRW-2 RC4 TRW-3 RC6     TR Security Glass Swing Door and Curtain Wall System  Design examples   Single leaf:  Minimum Size: Width = 600mm, Height = 1500mm Maximum Size: Width = 1000mm, Height = 2500mm Fixed panel:  Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.   TR Security Glass Swing Door and Curtain Wall System  Section examples       Types   Thickness of bullet proof steel plate/mm   Thickness of Glass/mm   EN1627-EN1630 Forced entry resistance   EN1063 Bullet resistance   UL752 Bullet resistance TRD-1  2.5-15 47.5-70 RC3      B1-B7      Level 1-8   TRD-2 RC4 TRD-3 RC6     TR Security Glass Sliding Door System Design examples
  • Bulletproof FB7(Br7)
    1. Bulletproof Glass System: Bullet Resistance Performance   Standards TR1 TR2 TR3 notes Corresponding Burglarproof resistance performance RC3 RC4 RC6   According to different requirements, clients can customize your TR systems with different bullet resistance performance. European Standards EN1522 Windows, doors, shutters and blinds—Bullet resistance—Requirements and classification  B1 B2-4 B5-7       American Standard   Systems   Rating   Ammunition   Grain   (g)   Minimum velocity fps         (m/s)   Number of shots               UL752 Standard for safety Bullet-Resisting Equipment             All TR systems can be customized with bullet resistance performance from one kind of the ratings based on your requirements.   Level 1   9 mm full metal copper jacket with lead core   124   8.0   1,175       358   3   Level 2   .357 Magnum jacketed lead soft point   158   10.2   1,250       381   3   Level 3   .44 Magnum lead semi-wadcutter gas checked   240   15.6   1,350       411   3   Level 4   .30 caliber rifle lead core soft point   180   11.7   2,540      774   1   Level 5   7.62 mm Rifle lead core full metal copper jacket military ball   150   9.7   2,750      838   1   Level 6   9 mm full metal copper jacket with lead core   124   8.0   1,400       427   5   Level 7   5.56 mm Rifle full metal copper jacket with lead core   55   3.56   3,080       939   5   Level 8   7.62 mm Rifle lead core full metal copper jacket, military ball   150   9.7   2,750       838   5   Note — Maximum velocity is 110 percent of the minimum velocity.     2. More Performances: Building physics Besides KFORTS high security performance, TR system complies with all requirements in building physics up to highest level. It features a slim frame, a concealed sash design, and a wide visible area. Resistance against wind load Water tightness Air permeability Technical parameters: ≥ 16kpa/m ³ (1800 * 1500), Technical parameters: ≥ 700 (PA), Technical parameters:The unit seam length index value is ≤ 0.5m ³ (m · h),The unit area index value is ≤ 1.4 square meters (m · h),Level: 8 (max). Air permeability Sound Insulation Standard: EN673 Standard: GB/T 8485-2008, Technical parameters: 1.87-2.15 W/(㎡· k) Door: 2.158 W/(㎡· k) Window: 1.875 W/(㎡· k) Curtain Wall: 1.873 W/(㎡· k) Technical parameters: ≥ 45 (dB (A)),           3. Design and Sections TR Security Glass Window System  Design examples Single leaf:  Minimum Size: Width = 500mm, Height = 750mm Maximum Size: Width = 800mm, Height = 1800mm Fixed panel:  Minimum Size: Width = 400mm, Height = 400mm Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.      TR Security Glass Window System   Section Examples       Types   Thickness of bullet proof steel plate/mm   Thickness of Glass/mm   EN1627-EN1630 Forced entry resistance   EN1063 Bullet resistance   UL752 Bullet resistance TRW-1  2.5-15 47.5-70 RC3      B1-B7      Level 1-8   TRW-2 RC4 TRW-3 RC6     TR Security Glass Swing Door and Curtain Wall System  Design examples   Single leaf:  Minimum Size: Width = 600mm, Height = 1500mm Maximum Size: Width = 1000mm, Height = 2500mm Fixed panel:  Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.   TR Security Glass Swing Door and Curtain Wall System  Section examples       Types   Thickness of bullet proof steel plate/mm   Thickness of Glass/mm   EN1627-EN1630 Forced entry resistance   EN1063 Bullet resistance   UL752 Bullet resistance TRD-1  2.5-15 47.5-70 RC3      B1-B7      Level 1-8   TRD-2 RC4 TRD-3 RC6     TR Security Glass Sliding Door System Design examples
  • Bulletproof LIL752 Level 1-8
    1. Bulletproof Glass System: Bullet Resistance Performance   Standards TR1 TR2 TR3 notes Corresponding Burglarproof resistance performance RC3 RC4 RC6   According to different requirements, clients can customize your TR systems with different bullet resistance performance. European Standards EN1522 Windows, doors, shutters and blinds—Bullet resistance—Requirements and classification  B1 B2-4 B5-7       American Standard   Systems   Rating   Ammunition   Grain   (g)   Minimum velocity fps         (m/s)   Number of shots               UL752 Standard for safety Bullet-Resisting Equipment             All TR systems can be customized with bullet resistance performance from one kind of the ratings based on your requirements.   Level 1   9 mm full metal copper jacket with lead core   124   8.0   1,175       358   3   Level 2   .357 Magnum jacketed lead soft point   158   10.2   1,250       381   3   Level 3   .44 Magnum lead semi-wadcutter gas checked   240   15.6   1,350       411   3   Level 4   .30 caliber rifle lead core soft point   180   11.7   2,540      774   1   Level 5   7.62 mm Rifle lead core full metal copper jacket military ball   150   9.7   2,750      838   1   Level 6   9 mm full metal copper jacket with lead core   124   8.0   1,400       427   5   Level 7   5.56 mm Rifle full metal copper jacket with lead core   55   3.56   3,080       939   5   Level 8   7.62 mm Rifle lead core full metal copper jacket, military ball   150   9.7   2,750       838   5   Note — Maximum velocity is 110 percent of the minimum velocity.     2. More Performances: Building physics Besides KFORTS high security performance, TR system complies with all requirements in building physics up to highest level. It features a slim frame, a concealed sash design, and a wide visible area. Resistance against wind load Water tightness Air permeability Technical parameters: ≥ 16kpa/m ³ (1800 * 1500), Technical parameters: ≥ 700 (PA), Technical parameters:The unit seam length index value is ≤ 0.5m ³ (m · h),The unit area index value is ≤ 1.4 square meters (m · h),Level: 8 (max). Air permeability Sound Insulation Standard: EN673 Standard: GB/T 8485-2008, Technical parameters: 1.87-2.15 W/(㎡· k) Door: 2.158 W/(㎡· k) Window: 1.875 W/(㎡· k) Curtain Wall: 1.873 W/(㎡· k) Technical parameters: ≥ 45 (dB (A)),           3. Design and Sections TR Security Glass Window System  Design examples Single leaf:  Minimum Size: Width = 500mm, Height = 750mm Maximum Size: Width = 800mm, Height = 1800mm Fixed panel:  Minimum Size: Width = 400mm, Height = 400mm Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.      TR Security Glass Window System   Section Examples       Types   Thickness of bullet proof steel plate/mm   Thickness of Glass/mm   EN1627-EN1630 Forced entry resistance   EN1063 Bullet resistance   UL752 Bullet resistance TRW-1  2.5-15 47.5-70 RC3      B1-B7      Level 1-8   TRW-2 RC4 TRW-3 RC6     TR Security Glass Swing Door and Curtain Wall System  Design examples   Single leaf:  Minimum Size: Width = 600mm, Height = 1500mm Maximum Size: Width = 1000mm, Height = 2500mm Fixed panel:  Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.   TR Security Glass Swing Door and Curtain Wall System  Section examples       Types   Thickness of bullet proof steel plate/mm   Thickness of Glass/mm   EN1627-EN1630 Forced entry resistance   EN1063 Bullet resistance   UL752 Bullet resistance TRD-1  2.5-15 47.5-70 RC3      B1-B7      Level 1-8   TRD-2 RC4 TRD-3 RC6     TR Security Glass Sliding Door System Design examples
  • Burglarproof RC6(P8B)
    1. Burglarproof Glass System: Burglar Resistance Performance     Standards TR1 TR2 TR3 notes European Standards EN1627 Pedestrian doorsets, windows, curtain walling, grilles and shutters—Burglarproof resistance—Requirements and classification RC3 RC4 RC6* Note*: KFORTS TR series includes glass door systems, window systems, curtain wall systems, etc. KFORTS can customize your products with one or more resistance performance based on your requirements. EN1628 Pedestrian doorsets, windows, curtain walling, grilles and shutters—Burglarproof resistance—Test method for the determination of resistance under static loading 6KN 10KN 15KN EN1629 Pedestrian doorsets, windows, curtain walling, grilles and shutters—Burglarproof resistance—Test method for the determination of resistance under dynamic loading Resist 50KG pendulum impactor from a height of 750mm. No test.** No test.** EN1630 Pedestrian doorsets, windows, curtain walling, grilles and shutters—Burglarproof resistance—Test method for the determination of resistance to manual burglary attempts Resist tools specified in RC1-RC3 systems, such as 700mm length crowbars and hand drills. Resist tools specified in RC1-RC4 systems, such as 0.8KG weight axes and battery drills. Resist tools specified in RC1-RC6 systems, such as 1.1KW saber saws and 2.3KW angle grinders. Note **: The purpose of EN1629 dynamic impact test is to simulate human attacks without the use of tools, such as shoulder strikes or kicks. When testing RC4-6 systems, the static load shall far exceed the dynamic load, which will not be achieved manually. Therefore, RC4-6 systems do not require dynamic mechanical test. EN356 Glass in building—Security glazing—Testing and classification of resistance against manual attack P5A Resist impact 3 times by a ∅ 100mm diameter, 4.11KG weight steel ball from the 9 meters height. P6B Resist 30-50 times of the impact by a 2KG axe. P8B Resist over 70 times of the impact by a 2KG axe.         2. Tools and Firearms that TR systems can resist The resistance performance of TR3 system is equivalent to RC6 resistance level in European standards. TR3 system can withstand destructive tools and firearms as follows.       Figure 3: Set of Tools C   Tool number Tool specification description C.1 Spalling hammer; length (800 + 50) mm, head weight (3,5 ± 0,25) kg C.2 Discs; Ø 230 mm maxi, thickness 3,0 mm (for steel or stone excluding diamond) C.3 Saw blades; bimetal C.4 Steel wedges; length (200 ± 10) mm, width (80 ± 10) mm, height (40 ± 5) mm C.5 Electric jig saw; nominal 650 W± 10 % C.6 Angle grinder; Nominal 2 300 W± 10 %, disc diameter max 230 mm C.7 Electric drill; Nominal 1 050 W± 10 %, with percussion action C.8 Submachine gun; Gun Type 56 with 7,62 mm bullets C.9 Sniper rifle; Gun Type 79 with 7,62 mm bullets     3. More Performances: Building physics Besides KFORTS high security performance, TR system complies with all requirements in building physics up to highest level. It features a slim frame, a concealed sash design, and a wide visible area. Resistance against wind load Water tightness Air permeability Technical parameters: ≥ 16kpa/m ³ (1800 * 1500), Technical parameters: ≥ 700 (PA), Technical parameters:The unit seam length index value is ≤ 0.5m ³ (m · h),The unit area index value is ≤ 1.4 square meters (m · h),Level: 8 (max). Air permeability Sound Insulation Standard: EN673 Standard: GB/T 8485-2008, Technical parameters: 1.87-2.15 W/(㎡· k) Door: 2.158 W/(㎡· k) Window: 1.875 W/(㎡· k) Curtain Wall: 1.873 W/(㎡· k) Technical parameters: ≥ 45 (dB (A)),           4. Design and Sections TR Security Glass Window System  Design examples Single leaf:  Minimum Size: Width = 500mm, Height = 750mm Maximum Size: Width = 800mm, Height = 1800mm Fixed Sash:  Minimum Size: Width = 400mm, Height = 400mm Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.      TR Security Glass Window System   Section Examples     Types Thickness of bullet proof steel plate/mm Thickness of Glass/mm EN1627-EN1630 Forced entry resistance EN1063 Bullet resistance UL752 Bullet resistance TRW-1  2.5-15 47.5-70 RC3      B1-B7   Level 1-8   TRW-2 RC4 TRW-3 RC6     TR Security Glass Swing Door and Curtain Wall System  Design examples       TR Security Glass Swing Door and Curtain Wall System  Section examples     Types Thickness of bullet proof steel plate/mm Thickness of Glass/mm EN1627-EN1630 Forced entry resistance EN1063 Bullet resistance UL752 Bullet resistance TRD-1  2.5-15 47.5-70 RC3      B1-B7   Level 1-8   TRD-2 RC4 TRD-3 RC6     TR Security Glass Sliding Door System Design examples Single leaf:  Minimum Size: Width = 600mm, Height = 1500mm Maximum Size: Width = 1000mm, Height = 2500mm Fixed panel:  Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.       TR Security Glass Sliding Door System               Section examples       Types Thickness of bullet proof steel plate/mm Thickness of Glass/mm EN1627-EN1630 Forced entry resistance EN1063 Bullet resistance UL752 Bullet resistance TRS-1  2.5-15 47.5-70 RC3      B1-B7   Level 1-8   TRS-2 RC4 TRS-3 RC6
  • Burglarproof RC5(P7B)
    1. Burglarproof Glass System: Burglar Resistance Performance     Standards TR1 TR2 TR3 notes European Standards EN1627 Pedestrian doorsets, windows, curtain walling, grilles and shutters—Burglarproof resistance—Requirements and classification RC3 RC4 RC6* Note*: KFORTS TR series includes glass door systems, window systems, curtain wall systems, etc. KFORTS can customize your products with one or more resistance performance based on your requirements. EN1628 Pedestrian doorsets, windows, curtain walling, grilles and shutters—Burglarproof resistance—Test method for the determination of resistance under static loading 6KN 10KN 15KN EN1629 Pedestrian doorsets, windows, curtain walling, grilles and shutters—Burglarproof resistance—Test method for the determination of resistance under dynamic loading Resist 50KG pendulum impactor from a height of 750mm. No test.** No test.** EN1630 Pedestrian doorsets, windows, curtain walling, grilles and shutters—Burglarproof resistance—Test method for the determination of resistance to manual burglary attempts Resist tools specified in RC1-RC3 systems, such as 700mm length crowbars and hand drills. Resist tools specified in RC1-RC4 systems, such as 0.8KG weight axes and battery drills. Resist tools specified in RC1-RC6 systems, such as 1.1KW saber saws and 2.3KW angle grinders. Note **: The purpose of EN1629 dynamic impact test is to simulate human attacks without the use of tools, such as shoulder strikes or kicks. When testing RC4-6 systems, the static load shall far exceed the dynamic load, which will not be achieved manually. Therefore, RC4-6 systems do not require dynamic mechanical test. EN356 Glass in building—Security glazing—Testing and classification of resistance against manual attack P5A Resist impact 3 times by a ∅ 100mm diameter, 4.11KG weight steel ball from the 9 meters height. P6B Resist 30-50 times of the impact by a 2KG axe. P8B Resist over 70 times of the impact by a 2KG axe.         2. Tools and Firearms that TR systems can resist The resistance performance of TR3 system is equivalent to RC6 resistance level in European standards. TR3 system can withstand destructive tools and firearms as follows.       Figure 3: Set of Tools C   Tool number Tool specification description C.1 Spalling hammer; length (800 + 50) mm, head weight (3,5 ± 0,25) kg C.2 Discs; Ø 230 mm maxi, thickness 3,0 mm (for steel or stone excluding diamond) C.3 Saw blades; bimetal C.4 Steel wedges; length (200 ± 10) mm, width (80 ± 10) mm, height (40 ± 5) mm C.5 Electric jig saw; nominal 650 W± 10 % C.6 Angle grinder; Nominal 2 300 W± 10 %, disc diameter max 230 mm C.7 Electric drill; Nominal 1 050 W± 10 %, with percussion action C.8 Submachine gun; Gun Type 56 with 7,62 mm bullets C.9 Sniper rifle; Gun Type 79 with 7,62 mm bullets     3. More Performances: Building physics Besides KFORTS high security performance, TR system complies with all requirements in building physics up to highest level. It features a slim frame, a concealed sash design, and a wide visible area. Resistance against wind load Water tightness Air permeability Technical parameters: ≥ 16kpa/m ³ (1800 * 1500), Technical parameters: ≥ 700 (PA), Technical parameters:The unit seam length index value is ≤ 0.5m ³ (m · h),The unit area index value is ≤ 1.4 square meters (m · h),Level: 8 (max). Air permeability Sound Insulation Standard: EN673 Standard: GB/T 8485-2008, Technical parameters: 1.87-2.15 W/(㎡· k) Door: 2.158 W/(㎡· k) Window: 1.875 W/(㎡· k) Curtain Wall: 1.873 W/(㎡· k) Technical parameters: ≥ 45 (dB (A)),           4. Design and Sections TR Security Glass Window System  Design examples Single leaf:  Minimum Size: Width = 500mm, Height = 750mm Maximum Size: Width = 800mm, Height = 1800mm Fixed Sash:  Minimum Size: Width = 400mm, Height = 400mm Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.      TR Security Glass Window System   Section Examples     Types Thickness of bullet proof steel plate/mm Thickness of Glass/mm EN1627-EN1630 Forced entry resistance EN1063 Bullet resistance UL752 Bullet resistance TRW-1  2.5-15 47.5-70 RC3      B1-B7   Level 1-8   TRW-2 RC4 TRW-3 RC6     TR Security Glass Swing Door and Curtain Wall System  Design examples       TR Security Glass Swing Door and Curtain Wall System  Section examples     Types Thickness of bullet proof steel plate/mm Thickness of Glass/mm EN1627-EN1630 Forced entry resistance EN1063 Bullet resistance UL752 Bullet resistance TRD-1  2.5-15 47.5-70 RC3      B1-B7   Level 1-8   TRD-2 RC4 TRD-3 RC6     TR Security Glass Sliding Door System Design examples Single leaf:  Minimum Size: Width = 600mm, Height = 1500mm Maximum Size: Width = 1000mm, Height = 2500mm Fixed panel:  Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.       TR Security Glass Sliding Door System               Section examples       Types Thickness of bullet proof steel plate/mm Thickness of Glass/mm EN1627-EN1630 Forced entry resistance EN1063 Bullet resistance UL752 Bullet resistance TRS-1  2.5-15 47.5-70 RC3      B1-B7   Level 1-8   TRS-2 RC4 TRS-3 RC6
1 2 3 4

A total of 4 pages

News letter
Join our mailing list, you will get new product release and event information as soon as possible later
Leave A Message
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

skype

whatsapp