1 results found for "Fire Rated Fire Rated Partition (1hour/2hours)"
  • Fire Rated Fire Rated Partition (1hour/2hours)
    1. Fire Resistance Performance of Products     I) Fire Rated Glass Door Systems Standard Ei60-D1/D2 Ei120-D2   Singapore Standard SS332:2018+A1:2022 Specifications for Fire Doors Integrity and insulation meet the standard for 60 minutes. Integrity and insulation meet the standard for 120 minutes.            II) Fire Rated Glass Door&Partition Systems Standard Ei60-W1 Ei120-W1   European and Singapore Standards SS332:2018+A1:2022 for Doors and EN1364-3 for Partitions Integrity and insulation meet the standard for 60 minutes. Integrity and insulation meet the standard for 120 minutes.     2. Types of Doors     Rating System Glass Thickness (mm) Size (Per Panel) (W*H) Frame Size (T*W) Remarks 1 Hour Ei60-D1 25 1320*2959 78*100 Full Insulated Glass 1 Hour   Ei60-D2 25   1328*2972   78*75 Full Insulated Glass 2 Hours Ei120-D1 45 1223*3082 105*85 Full Insulated Glass   3. Glass   Glass used in KFORTS systems is made of multilayers of toughened glass and the special nc-Si fire-resistant materials. Kforts glass, which is shatter proof and against impact or cutting injuries, has passed EN12600 impact test. The optical clarity of our glass is equivalent to that of clear float glass.    4. Frame The Frame consists of a structural steel-aluminum core cladded with fire rated and insulated panels. All the framing systems have been tested and passed the requirement stipulated under the by-laws and regulations.   5. Finishes The glass can be ceramic, reflected, sandblasted, carved or etched. The frame can be cladded with aluminum in coating, timber veneer, stainless steel or others.    6. By Laws and Regulations: I)Fire safety a. Singapore Standard SS332:2018+A1:2022 for fire resistant doors. b. European Standard EN1364-3 for fire resistant partitions. b. TUV certification and listing。         II)Mechanical Test The Classification 1(B)1 of EN12600 Impact Test.   7. Consultancy We will offer the following advice and consultation: I)Product Qualification Certificate. II) Fire Resistance Test Report. III) Product Labeling. IV)COC Certification.       8. Design and Sections   I)Design Examples of Fire Rated Glass Door&Partition Systems  II)Sections of Fire Rated Glass Door&Partition Systems a. Ei60-D1/Ei60-W1 (1 hour)   b. Ei120-D1/Ei120-W1 (2 hours)

A total of 1 pages

News letter
Join our mailing list, you will get new product release and event information as soon as possible later
Leave A Message
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

skype

whatsapp