Bulletproof FB6(Br6)
1. Bulletproof Glass System: Bullet Resistance Performance
Standards
TR1
TR2
TR3
notes
Corresponding Burglarproof resistance performance
RC3
RC4
RC6
According to different requirements, clients can customize your TR systems with different bullet resistance performance.
European Standards
EN1522
Windows, doors, shutters and blinds—Bullet resistance—Requirements and classification
B1
B2-4
B5-7
American
Standard
Systems
Rating
Ammunition
Grain
(g)
Minimum velocity
fps (m/s)
Number of shots
UL752
Standard for safety
Bullet-Resisting Equipment
All TR systems can be customized with bullet resistance performance from one kind of the ratings based on your requirements.
Level 1
9 mm full metal copper jacket with lead core
124
8.0
1,175 358
3
Level 2
.357 Magnum jacketed lead soft point
158
10.2
1,250 381
3
Level 3
.44 Magnum lead semi-wadcutter gas checked
240
15.6
1,350 411
3
Level 4
.30 caliber rifle lead core soft point
180
11.7
2,540 774
1
Level 5
7.62 mm Rifle lead core full metal copper jacket military ball
150
9.7
2,750 838
1
Level 6
9 mm full metal copper jacket with lead core
124
8.0
1,400 427
5
Level 7
5.56 mm Rifle full metal copper jacket with lead core
55
3.56
3,080 939
5
Level 8
7.62 mm Rifle lead core full metal copper jacket, military ball
150
9.7
2,750 838
5
Note — Maximum velocity is 110 percent of the minimum velocity.
2. More Performances: Building physics
Besides KFORTS high security performance, TR system complies with all requirements in building physics up to highest level. It features a slim frame, a concealed sash design, and a wide visible area.
Resistance against wind load
Water tightness
Air permeability
Technical parameters: ≥ 16kpa/m ³ (1800 * 1500),
Technical parameters: ≥ 700 (PA),
Technical parameters:The unit seam length index value is ≤ 0.5m ³ (m · h),The unit area index value is ≤ 1.4 square meters (m · h),Level: 8 (max).
Air permeability
Sound Insulation
Standard: EN673
Standard: GB/T 8485-2008,
Technical parameters: 1.87-2.15 W/(㎡· k)
Door: 2.158 W/(㎡· k)
Window: 1.875 W/(㎡· k)
Curtain Wall: 1.873 W/(㎡· k)
Technical parameters: ≥ 45 (dB (A)),
3. Design and Sections
TR Security Glass Window System
Design examples
Single leaf:
Minimum Size: Width = 500mm, Height = 750mm
Maximum Size: Width = 800mm, Height = 1800mm
Fixed panel:
Minimum Size: Width = 400mm, Height = 400mm
Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.
TR Security Glass Window System
Section Examples
Types
Thickness of bullet proof steel plate/mm
Thickness of Glass/mm
EN1627-EN1630
Forced entry resistance
EN1063
Bullet resistance
UL752
Bullet resistance
TRW-1
2.5-15
47.5-70
RC3
B1-B7
Level 1-8
TRW-2
RC4
TRW-3
RC6
TR Security Glass Swing Door and Curtain Wall System
Design examples
Single leaf:
Minimum Size: Width = 600mm, Height = 1500mm
Maximum Size: Width = 1000mm, Height = 2500mm
Fixed panel:
Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.
TR Security Glass Swing Door and Curtain Wall System
Section examples
Types
Thickness of bullet proof steel plate/mm
Thickness of Glass/mm
EN1627-EN1630
Forced entry resistance
EN1063
Bullet resistance
UL752
Bullet resistance
TRD-1
2.5-15
47.5-70
RC3
B1-B7
Level 1-8
TRD-2
RC4
TRD-3
RC6
TR Security Glass Sliding Door System